Project supply for builders, integrators and designers across Australia

CESP · Ex floodlights

Hazardous Location LED Flood Light - Class 1 Division 2 - U-Bracket Mount - 120W/150W/185W

SKUCESP-J-168

CESP Ex floodlights · Explosion-proof lighting. Specified, quoted and supplied by Project Supplies for commercial projects.

Hazardous-area schemeUL HazLoc (Class I, Division 2)
PowerMax 185W
Input voltageAC100-240/277V, 50/60Hz
Luminous efficacyup to 120 LPW
Price on requestQuoted for your configuration and quantity.
Technical clarificationHazardous-area ratings, Ex markings and certificate references are as published by CESP and are not independently verified. Confirm the certificate, marking and conditions of use for the exact model against the area classification before ordering. In Australia, hazardous-area equipment normally requires IECEx or ANZEx certification, and installation and inspection must follow AS/NZS 60079 by competent persons.
Project Supplies specification sheet

Confirm the specification and quotation before ordering.

Product introduction

Ex floodlights

Explosion-proof floodlights · UL HazLoc (Class I, Division 2). Max 185W · -40°C to +55°C. Applications: Wastewater treatment, oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors….

Key data: hazardous-area scheme UL HazLoc (Class I, Division 2); power Max 185W; input voltage AC100-240/277V, 50/60Hz; luminous efficacy up to 120 LPW.

Every order starts with an RFQ: we confirm the exact variant, options, lead time and commercial terms in an itemised quotation before anything is ordered.

Hazardous-area schemeUL HazLoc (Class I, Division 2)

PowerMax 185W

Input voltageAC100-240/277V, 50/60Hz

Luminous efficacyup to 120 LPW

Colour temperature3000K/4000K/5000K/5700K/6500K

Beam angle108°, 120°

Power factor0.97

Dimensions400x400x169mm

Specifications

The technical details.

Download specification sheet
Hazardous-area scheme
UL HazLoc (Class I, Division 2)
Collection
Ex floodlights
Series
CES-J
Power
Max 185W
Input voltage
AC100-240/277V, 50/60Hz
Luminous efficacy
up to 120 LPW
Colour temperature
3000K/4000K/5000K/5700K/6500K
Beam angle
108°, 120°
Operating temperature
-40°C to +55°C
Power factor
0.97
LED package
3030
LED driver
Meanwell HLG series
Housing
Aluminum alloy (ADC12 )
Lens
tempered glass
Cable entry
NPT 3/4”-14
Dimensions
400x400x169mm
Weight
10.5kg
Temperature class
T5
Ex marking (as published)
Applies to hazardous locations of Class I, Division 2 with explosive gas atmosphere.; Class I, Division 2, Groups A, B, C and D